Goodwe Inverter, GM1000 MODBUS registers: read online

Connect Goodwe to the computer through a USB-to-serial or RS485 adapter and read its registers in your browser: click "Read register values online" under the model (Chrome or Edge, nothing to install). The tables below list the MODBUS offset, unit, data type and scale of every register shown. For logging 24/7 into a database, CSV files or Excel, use the Advanced Serial Data Logger (for MODBUS RTU) or Advanced TCP/IP Data Logger (for MODBUS TCP): they poll the complete map of every model on this page and provide continuous Goodwe modbus logging and log.

Do you not know the meter address? Scan the device address online

Goodwe (Inverter,GM1000) - MODBUS Maps

Registers in the map: 71 (the first 50 are listed below; the browser reader and the data loggers use the complete map). function 3 (holding registers). byte order big-endian. data types: dword, word.

MODBUS offsetDescriptionUnitsData typeScale
790Firmware version word 
852Firmware version of ARM word 
768VpvI /PV1 input voltage word×0.1
769Vpv2 /PV2 input voltage word×0.1
770Ipv1 /PV1 input current word×0.1
771Ipv2 /PV2 input current word×0.1
772Vac1 /L1 phase voltage word×0.1
773Vac2 /L2 phase voltage word×0.1
774Vac3 /L3 phase voltage word×0.1
775Lac1 /L1 phase current word×0.1
776Lac2 /L2 phase currentAword×0.1
777Lac3 /L3 phase currentAword×0.1
778Fac1 /L1 phase frequencyHzword×0.01
779Fac2 /L2 phase frequencyHzword×0.01
780Fac3 /L3 phase frequencyHzword×0.01
781Pac L /Inverter current output powerWword 
782Work mode word 
783Inverter internal temperaturedeg Cword×0.1
784Error message H word 
785Error message word 
786Total feed power to grid/Total power generationkWhdword×0.1
788Total feeding hours/Hourly power generationhdword 
791Warning code word 
793Function status bits word 
796BUS voltage word×0.1
797NBUS voltage word×0.1
799Safety codeImAword 
800Feed power to grid in today/ daily power generationkWhword×0.1
804VpvS /PVS input voltage word×0.1
805Ipv5 /PVS input current word×0.1
806Voltage word×0.1
807Ipv6 /PV6 input current word×0.1
827Year :month word 
828Date :hour word 
830Manufacture ID word 
831Wireless signal strength%word 
832High byte of PV mode (SMT only) word 
833Low byte of PV mode (SMT only) word 
850PowerWdword 
853GPRS burn-in mode word 
854Pac H /High byte of powerWword 
855Vpv3 /PV3 input voltage word×0.1
856Vpv4 /PV4 input voltage word×0.1
857Ipv3 /PV3 input current word×0.1
858Ipv4 /PV4 input current word×0.1
859Istr1/PV string1 current word×0.1
860Istr2/PV string2 current word×0.1
861Istr3/PV string3 current word×0.1
862Istr4/PV string4 current word×0.1
863Istr5/PV string5 current word×0.1

This is not the complete map: 50 of 71 registers are listed above. Click "Read register values online" to read any register of your device in the browser, or download the program to log the complete map.