Nortel Norstar Standard SMDR setup and CDR format
This page shows how to get call records out of the Nortel Norstar Standard into Advanced PBX Data Logger: the connection settings, the parser to select and the 16 fields the logger extracts for reports or a database. The settings apply to our logger; other call accounting software may expect a different configuration.
Quick facts
| Item | Nortel Norstar Standard |
|---|---|
| Interface | Serial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format. |
| Parser to select | Nortel Norstar Standard |
| Fields extracted | 16 |
| Other Nortel systems | Nortel Meridian and Norstar SMDR formats |
| SMDR6 printer baud rate, default (documented) | 1200 (options 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200) |
Station Message Detail Recording 6 (SMDR6)
The Station Message Detail Recording 6 (SMDR6) is a unit that connects to your Norstar Key System Unit (KSU) to record call activity. Each time a telephone call is made to or from your company, the information about the call is recorded. When the call is completed, information about the call is printed out in Call Records
Programming SMDR6
To access the SMDR6 Administration menu press [Feature] [9] [*] [2]. The display shows: SMDR6 Admin. Then configure following options as:
- Printer: 38400 (press [CHANGE] to set new baudrate)
- Format: SL-1 or SL-1 CLID (press [SHOW] then [CHANGE])
- Report: All (output info about all calls)
- Language: English
- Access codes: leave unchanged
- Feature: F999
Note: If you use M7100/M7208 telephones for programming SMDR6 use following buttons as:
- [*] - NEXT
- [O] - SHOW
- [#] - CHANGE
Errors
When you use the FEATURE 9 * 2 code you may see some error messages:
INACTIVE FEATURE. That error message indicates that there is a problem with the connection between the phone system and the SMDR6 box. That connection is made using a standard RJ11 telephone cord (the same type of cord you would use to plug a telephone).
PRINTER PROBLEM. This error appears if connection between the SMDR6 unit and a computer is broken or our software is not active. Please, verify the following: cable (you need a straight serial cable, not a NULL cable), a COM port number, baud rate, launch our software on your computer.
Configuring PBX Logger
COM port settings
Set communication parameters:
- Baud rate: 38400
- Data bits: 8
- Parity: None
- Stop bits: 1
- Hardware flow control: enable all options
Modules
Module -> Query Parse Filter -> Parser -> [Nortel Norstar SL-1] or [Nortel Norstar SL-1 CLID]
Settings from the manufacturer's documentation
Taken from Norstar - smdr. Values are those stated in the documentation; confirm them against your firmware release.
| Setting | Documented value |
|---|---|
| SMDR6 printer baud rate, default | 1200 (options 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200) |
| SMDR6 record format default | SL-1 Standard; Norstar format is a third selectable option not listed on the page |
| SMDR6 AT-command PC administration port | 1200 baud, no parity, 8 data bits, 1 stop bit, hardware flow control (CTS/RTS) |
Selecting the correct parser for Nortel Norstar Standard

Nortel Norstar Standard
Nortel Norstar Standard
Data items
| Description | Data type | Column name |
|---|---|---|
| Call time | datetime | CALL_TIME |
| Line | string | TRUNK |
| Station | string | EXT |
| Direction | string | DIRECTION |
| Ring | datetime | RING |
| Phone | string | DIALED_PHONE |
| Caller phone | string | CALLER_PHONE |
| Name | string | ACC |
| DNIS number | string | DNIS |
| PRI service | string | FLAG2 |
| BC | string | FLAG3 |
| Hospitality | string | FLAG4 |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Record type | string | CALL_TYPE |
| Record type 1 | string | FLAG1 |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
<2012/04/16 03:54:19.734>*041612 035150 0250 9988 630xxxxxxx NAME SYST U A
<2012/04/16 03:54:49.296>*041612 035220 0250 2429 630xxxxxxx NAME SYST U T
<2012/04/16 03:55:14.452>-------- 04/16/12 03:51:35 LINE = 0023 STN = 2298
BC = SPEECH
PRI SERVICE PUBLIC
00:00:00 OUTGOING CALL
DIGITS DIALED 163xxxxxxxxxxxx
00:00:55 CALL RELEASED
*041612 035245 0250 2429 630xxxxxxx NAME SYST U R
-------- 04/16/12 03:51:50 LINE = 0250 STN = 9988
CALLING NUMBER 630xxxxxxx
NAME NAME SYST
UNKNOWN
DNIS NUMBER 9988
BC = SPEECH
00:00:00 INCOMING CALL RINGING 0:01
LINE = 0001
00:00:08 HOLD
00:00:30 TRANSFERRED
-------- 04/16/12 03:52:20 LINE = 0250 STN = 2429
00:00:00 FROM TRANSFER
00:00:00 UNHOLD
00:00:25 CALL RELEASED
<2012/04/16 08:02:21.073>*041612 075952 0250 9988 630xxxxxxx UNKNOWN U A
<2012/04/16 08:03:59.571>*041612 080130 0250 9988 630xxxxxxx UNKNOWN U R
Reports and a database
Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.
Related Nortel systems
Nortel Norstar SL1 StandardNortel Norstar SL1 CLID
Nortel Type 2
Onyx III
Nortel Meridian and Norstar SMDR formats
All supported PBX systems
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.
Related topics: Advanced PBX Data Logger
hereCall logging Call accounting SMDR to SQL SMDR Listener Cables and signals