bg

Panasonic KX-NS1000 SMDR setup and CDR format

This page shows how to get call records out of the Panasonic KX-NS1000 into Advanced PBX Data Logger: the connection settings, the parser to select and the 17 fields the logger extracts for reports or a database. The settings apply to our logger; other call accounting software may expect a different configuration.

Quick facts

ItemPanasonic KX-NS1000
InterfaceLAN. The PBX accepts a connection on TCP port 2300; the logger connects to the PBX IP address.
Port2300
Parser to selectPanasonic KX-NS1000
Fields extracted17
Other Panasonic systemsPanasonic KX-TDA30, TDA100, TDA200, TDA600 SMDR setup, Panasonic KX-T, KX-TD500, DBS and 576/816 SMDR formats

Printing Out SMDR Using LAN Port

Systems compatible: Panasonic KX-NS1000, Panasonic KX-NS700, Panasonic KX-NS500, Panasonic KX-NS300, Panasonic KX-NSX1000, Panasonic KX-NSX2000

1. Go to 11.1 Maintenance → Main.
2. Set Port to LAN.
3. Under Print Information select which items you would like to get in the SMDR output.
3.1 Date format: MM-DD-YY.
3.2 Time format: 24H.

SMDR Settings

4. Click on SMDR Options tab.
5. Note the default SMDR Port Number and Password. (These can be changed at your own discretion, but for this document we will use the default settings.)

SMDR Options

6. Configure our software to send password to the PBX.

By default, the Panasonic NS1000 system requires a username/password (default: SMDR/PCCSMDR) to connect to the TCP/IP feed.

You must activate the "Panasonic KX-NCP1000" data query plugin (the plugin name on the image below is just an example), click the "Setup" button and specify the password:

Note: this feature is available in the Trial, Professional and Enterprise versions only.

Date Format and Password

Activating SMDR records for all calls

On the "SMDR options" page just enable condition codes to enable call logging for all stages "RC" and "AN". "RC" stands for received and "AN" for answered.

PBX rejects connections

In this case the logger received "Rejected" when it tries to connect.

Solution: try to change the default SMDR TCP port number from 2300 to 22300 in everywhere (the PBX settings, the settings in our software), and reboot your PBX.

Configuring PBX Data Logger as a TCP client

Our software should work in the TCP client mode. It means that our software will initiate connection with the PBX and the PBX will work as a server. Add one or several PBX IP addresses here (the IP address of the Panasonic PBX). The port number should match the port that you have defined within the PBX (2300 in the example below).

1. Add a new configuration with the TCP data source (if you didn't it before).

TCP/IP Data Interface

2. Configure the TCP settings as shown below.

TCP Client Mode - Panasonic PBX

192.168.1.220

2300

192.168.1.220:2300

Selecting the correct parser for Panasonic KX-NS1000

Parser Selection For PBX Data Logger

Panasonic KX-NS1000

Panasonic KX-NS1000

Data items

DescriptionData typeColumn name
Call datedatetimeCALL_DATE
Call time onlydatetimeCALL_TIME2
Call date and timedatetimeCALL_TIME
ExtensionstringEXT
COstringTRUNK
DirectionstringDIRECTION
Call typestringCALL_TYPE
DID name and numberstringDNIS
Caller numberstringCALLER_PHONE
Caller namestringFLAG3
Dialed numberstringDIALED_PHONE
RingdatetimeRING
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
CostfloatCOST
Account codestringACC
Condition codestringFLAG1

Panasonic programming software

Panasonic KX-NS and KX-HTS systems are programmed in the Web Maintenance Console, opened in a browser at the IP address of the PBX. It is part of the system, not a download from AGG Software. The SMDR settings described on this page are made there; PBX Data Logger receives the records the console switches on.

Reads Panasonic KX-NS1000 records over TCP port 2300. The parser is built in - 18 fields extracted.

Reports and a database

Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.

Related Panasonic systems

Panasonic KX-NCP500
Panasonic KX-NCP1000
Panasonic KX-NS300-NS500-NS700
Panasonic KX-NSX1000
Panasonic KX-TDA30, TDA100, TDA200, TDA600 SMDR setup
Panasonic KX-T, KX-TD500, DBS and 576/816 SMDR formats
All supported PBX systems