ENTES (EPM-07) data logging. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
152L3 phase min. Apparent powerVAword
154Total min. Import active powerWattinteger
156Total min. Export active powerWattinteger
158Total min. Import reactive powerVarinteger
160Total min. Export reactive powerVarinteger
162Total min. Apparent powerVAword
164L1 phase max. VoltageVoltword
166L2 phase max. VoltageVoltword
168L3 phase max. VoltageVoltword
170L1 L2 phase phase max. VoltageVoltword
172L2 L3 phase phase max. VoltageVoltword
174L3 L1 phase phase max. VoltageVoltword
176L1 phase max. CurrentAmperword
178L2 phase max. CurrentAmperword
180L3 phase max. CurrentAmperword
182L1 phase max. Active powerWattinteger
184L2 phase max. Active powerWattinteger
186L3 phase max. Active powerWattinteger
188L1 phase max. Reactive powerVarinteger
190L2 phase max. Reactive powerVarinteger
192L3 phase max. Reactive powerVarinteger
194L1 phase max. Apparent powerVAword
196L2 phase max. Apparent powerVAword
198L3 phase max. Apparent powerVAword
200Total max. Import active powerWattinteger
202Total max. Export active powerWattinteger
204Total max. Import reactive powerVarinteger
206Total max. Export reactive powerVarinteger
208Total max. Apparent powerVAword
210L1 phase max. Current demandAmperword
212L2 phase max. Current demandAmperword
214L3 phase max. Current demandAmperword
216L1 phase import max. Demand active powerWattinteger
218L1 phase export max. Demand active powerWattinteger
220L2 phase import max. Demand active powerWattinteger
222L2 phase export max. Demand active powerWattinteger
224L3 phase import max. Demand active powerWattinteger
226L3 phase export max. Demand active powerWattinteger
228L1 phase import max. Demand reactive powerVarinteger
230L1 phase export max. Demand reactive powerVarinteger
232L2 phase import max. Demand reactive powerVarinteger
234L2 phase export max. Demand reactive powerVarinteger
236L3 phase import max. Demand reactive powerVarinteger
238L3 phase export max. Demand reactive powerVarinteger
240L1 phase max. Demand apparent powerVAword
242L2 phase max. Demand apparent powerVAword
244L3 phase max. Demand apparent powerVAword
246Total import max. Demand active powerWattinteger
248Total export max. Demand active powerWattinteger
250Total import max. Demand reactive powerVarinteger
252Total export max. Demand reactive powerVarinteger
254Total max. Demand apparent powerVAword
32768Voltage transformer ratio smallint
32769Current transformer ratio smallint
32770Calculation method smallint
32771Demand timeminutesmallint
32772Pulse ratio smallint
32773Pulse output 1 parameter setting smallint
32774Pulse output 2 parameter setting smallint
32775Energy counter 1 selection smallint
32776Energy counter 2 selection smallint
32777Communication address smallint
32778Baud rate smallint
32779Parity smallint
32780Password enable smallint
32781Password smallint

ENTES (EPM-07) data logging
ENTES (EPR04) data logging
ENTES (ES32) data logging
ENTES (MPR1 Series) data logging
ENTES (MPR2 Series) data logging
ENTES (MPR3 Series, MPR4 Series) data logging
ENTES (MPR60) data logging
ENTES (MPR63) data logging
ENTES (MPR7 Series) data logging

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.