Hybrex G1-824. SMDR/CDR data format and connection settings
This data is being extracted with help of the "Advanced PBX Data Logger" software only. It may not applicable for other software titles.
SMDR programming
14-01-02 - Record Incoming Calls: 0 (Enable)
14-01-04 - Record Unanswered Incoming Calls: 0 (Enable)
14-01-05 - Print Page Header: 0 (Enable - recommended)
14-01-06 - Number of Call Records To be Printed Between Headers: 99 (recommended)
Unlocking SMDR data
If your system is equipped with an RS-232 port and is using a printer to keep a telephone log, you can temporarily suspend the output of the RS-232 port
so you can change the paper on the printer or for any other reason where
the printer needs to go off line. If you lock the SMDR port, calls will be stored in the PBX until you re-enable the
port.
- Press SPK.
- Dial 7, 7, 2.
This will toggle the RS-232 port on or off.
If you have an LCD equipped telephone, the display will show the current status of the SMDR port. If it is on, the
display will show "SMDR IS UNLOCK." If it is off, the display will show "SMDR IS LOCK."
Configuring a COM port
The COM port number should match the number in your system. You can check the correct port number in Devices Manager → Ports.
1. Add a new configuration with the RS232 data source (if you didn't it before).
2. Select the COM port and configure the communication settings for your PBX corresponding to your PBX settings.
Selecting the correct parser for Hybrex G1-824
Data items
Description | Data type | Column name |
Extension | string | EXT |
Trunk number | string | TRUNK |
Record type | string | CALL_TYPE |
Call type | string | FLAG1 |
Direction | string | DIRECTION |
Account number | string | ACC |
Call time | datetime | CALL_TIME |
Call duration | datetime | CALL_DURATION |
Call duration (s) | integer | CALL_DURATION_S |
Ring | datetime | RING |
Interested in reports for PBX usage?
Our PBX Reports utility provides various reporting options—manual, scheduled, and through email—a built-in web server, and additional features. You can configure your call accounting system for Hybrex G1-824. Look here
Want PBX call logs in a database?
The logger, with its standard feature, ensures real-time capture and exportation of SMDR or CDR data to your database.. Follow this link
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.