bg

Mitel SX 200 EL SMDR setup and CDR format

This page shows how to get call records out of the Mitel SX 200 EL into Advanced PBX Data Logger: the connection settings, the parser to select and the 11 fields the logger extracts for reports or a database. The settings apply to our logger; other call accounting software may expect a different configuration.

Quick facts

ItemMitel SX 200 EL
InterfaceSerial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format.
Parser to selectMitel SX 200 EL
Fields extracted11
Other Mitel systemsMitel SX-200D, CS-5000 and Inter-Tel SMDR formats
default serial parameters for the 1103 Dataset circuit descriptor used to deliver SMDR (documented)Default Baud Rate 9600 (min 110, max 19200), Parity None, Character Length 8, Number of Stop Bits 1, Flow Control None

Settings from the manufacturer's documentation

Taken from Mitel CallAccounting InstallationGuide, Mitel SX-200 ICP Rev 3-1 Tech Handbook, Mitel SX-200D SMDR. Values are those stated in the documentation; confirm them against your firmware release.

SettingDocumented value
identity of manual's SX-200 sectionThis section of the Mitel Call Accounting Installation Guide is explicitly written for "SX-200 EL/ML 17 Release 4.0 and greater", matching this page's model
default serial parameters for the 1103 Dataset circuit descriptor used to deliver SMDRDefault Baud Rate 9600 (min 110, max 19200), Parity None, Character Length 8, Number of Stop Bits 1, Flow Control None
connection mediumRS-232 serial cable between the SX-200 and the Enterprise Server, co-located
SX-200 EL/ML support statusmanufacture discontinued and no longer supported by Mitel or prairieFyre; upgrade to SX-200 ICP recommended

Switching SMDR output on, as documented

  1. On the COS define Form, enable Extended SMDR or the SX-200 will truncate call record data.
  2. On the COS define Form, enable the SMDR - Records Incoming Calls option for every Class of Service currently in use.
  3. Enable SMDR reporting on the trunk groups for outbound calls via the Trunk Group Form.
  4. After programming the Directed I/O Form, also enable the report from the Maintenance Console application or it will not be generated.
  5. Program the Data Circuit Descriptor, Data Assignment and Directed I/O forms in that order to get SMDR data flowing from the SX-200 to the accounting server.

Record format notes

  • The Directed I/O Form's GUARANTEED field, only modifiable for SMDR and Data SMDR printouts, defaults to NO; set to YES to guarantee SMDR records print without loss.

Selecting the correct parser for Mitel SX 200 EL

Parser Selection For PBX Data Logger

Mitel SX 200 EL

Mitel SX 200 EL

Data items

DescriptionData typeColumn name
Call typestringCALL_TYPE
Call timedatetimeCALL_TIME
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
Calling partystringEXT
Caller phonestringCALLER_PHONE
AttendantstringFLAG2
PhonestringDIALED_PHONE
Call flagsstringFLAG1
TrunkstringTRUNK
Account codestringACC

Sample record

As delivered by the system; phone numbers, names and public addresses are masked.

 01/23 09:32  00:00:06 3090  9   923xxxx                    RT012       644xxxx      074
 01/23 09:32  00:00:24 3090  9   144xxxxx                   RT002       644xxxx      074
 01/24 04:06P 00:16:05 3243  9   929xxxx                    RT002       644xxxx      074

Reports and a database

Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.

Related Mitel systems

Mitel MiVoice Office 400
Mitel CS-5000
Mitel SX 2000
Mitel SX 200D
Mitel SX-200D, CS-5000 and Inter-Tel SMDR formats
All supported PBX systems

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.