Panasonic KX-TA308, TA616, TA624, TEB308, TEM824 SMDR setup
This page covers the Panasonic Panasonic KX-TA616, Panasonic KX-TA308, Panasonic KX-TA624, Panasonic KX-TEB308 and Panasonic KX-TEM824 variants in Advanced PBX Data Logger. Each section gives the connection settings, the parser to select and the fields the logger extracts for reports or a database; where the setup steps are the same for every variant they are given once. The settings apply to our logger; other call accounting software may expect a different configuration.
Quick facts
| Item | Panasonic KX-TA308, TA616, TA624, TEB308, TEM824 SMDR setup |
|---|---|
| Variants on this page | Panasonic KX-TA616, Panasonic KX-TA308, Panasonic KX-TA624, Panasonic KX-TEB308, Panasonic KX-TEM824 |
| Interface | Differs by variant; see each section. |
| Parsers | Panasonic KX-TA616, Panasonic KX-TA308, Panasonic KX-TA624, Panasonic KX-TEB308, Panasonic KX-TEM824 |
| Fields extracted | 8 to 9 |
| Other Panasonic systems | Panasonic KX-TDA30, TDA100, TDA200, TDA600 SMDR setup, Panasonic KX-T, KX-TD500, DBS and 576/816 SMDR formats |
Variants on this page
- Panasonic KX-TA616 · Serial, 9 fields
- Panasonic KX-TA308 · Serial, 9 fields
- Panasonic KX-TA624 · Serial printer port or LAN, whichever the system uses for SMDR output, 8 fields
- Panasonic KX-TEB308 · Serial printer port or LAN, whichever the system uses for SMDR output, 9 fields
- Panasonic KX-TEM824 · Serial printer port or LAN, whichever the system uses for SMDR output, 9 fields
Panasonic KX-TA616
Parser: Panasonic KX-TA616
Connection: Serial. The SMDR or printer port of the PBX is connected to a COM port; speed, data bits, parity and flow control must match the PBX.
Fields extracted: 9
Pinout and wiring
| PBX (9 pin female) | PC (9 pin female) | PC (25 pin female) |
|---|---|---|
| 2 | 3 | 2 |
| 3 | 2 | 3 |
| 4 | 6 | 5,6,8 |
| 5 | 5 | 7 |
| 6 | 4 | 20 |
| 7 | 8 | - |
| 8 | 7 | 20 |
Settings from the manufacturer's documentation
Taken from smdr pinout. Values are those stated in the documentation; confirm them against your firmware release.
| Setting | Documented value |
|---|---|
| Pinout (PBX 9-pin female -> PC 9-pin female -> PC 25-pin female) | 2-3-2, 3-2-3, 4-6-(5,6,8), 5-5-7, 6-4-20, 7-8-(none), 8-7-20 |
Data items: Panasonic KX-TA616
| Description | Data type | Column name |
|---|---|---|
| Call time | string | CALL_TIME |
| Extension | string | EXT |
| CO | string | TRUNK |
| Direction | string | DIRECTION |
| Dialed number | string | DIALED_PHONE |
| Caller | string | CALLER_PHONE |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Account | string | ACC |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
6/12/02 8:16PM 112 02 225608 00:00'14" .... 6/12/02 * 8:14PM 101 03 < incoming > 00:03'13" .... 6/12/02 8:18PM 108 03 552186 00:00'31" ....
Panasonic KX-TA308
Parser: Panasonic KX-TA308
Connection: Serial. The SMDR or printer port of the PBX is connected to a COM port; speed, data bits, parity and flow control must match the PBX.
Fields extracted: 9
Pinout and wiring
| PBX (9 pin female) | PC (9 pin female) | PC (25 pin female) |
|---|---|---|
| 2 | 3 | 2 |
| 3 | 2 | 3 |
| 4 | 6 | 5,6,8 |
| 5 | 5 | 7 |
| 6 | 4 | 20 |
| 7 | 8 | - |
| 8 | 7 | 20 |
Settings from the manufacturer's documentation
Taken from smdr pinout. Values are those stated in the documentation; confirm them against your firmware release.
| Setting | Documented value |
|---|---|
| Pinout (PBX 9-pin female -> PC 9-pin female -> PC 25-pin female) | 2-3-2, 3-2-3, 4-6-(5,6,8), 5-5-7, 6-4-20, 7-8-(none), 8-7-20 |
Data items: Panasonic KX-TA308
| Description | Data type | Column name |
|---|---|---|
| Call time | string | CALL_TIME |
| Extension | string | EXT |
| CO | string | TRUNK |
| Direction | string | DIRECTION |
| Dialed number | string | DIALED_PHONE |
| Caller | string | CALLER_PHONE |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Account | string | ACC |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
2/26/04 7:52PM 107 01 < DISA incoming > 00:00'15" .... 0 2/26/04 * 7:52PM 101 01 < DISA incoming > 00:00'31" .... 0 2/26/04 7:53PM 101 01 806xxxxxxxx 00:09'12" ....
Panasonic KX-TA624
Parser: Panasonic KX-TA624
Connection: Serial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format.
Fields extracted: 8
Data items: Panasonic KX-TA624
| Description | Data type | Column name |
|---|---|---|
| Call time | datetime | CALL_TIME |
| Extension | string | EXT |
| CO | string | TRUNK |
| Direction | string | DIRECTION |
| Dialed number | string | DIALED_PHONE |
| Caller | string | CALLER_PHONE |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
30/11/07 12:07PM 26 01 077xxxxxxxx 00:00'56" ... 30/11/07 12:14PM 29 01 023xxxxxxxx 00:00'09" . 30/11/07 12:15PM 29 02 012xxxxxxxx 00:00'40" ....
Panasonic KX-TEB308
Parser: Panasonic KX-TEB308
Connection: Serial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format.
Fields extracted: 9
Settings from the manufacturer's documentation
Taken from Panasonic KX-TEB 308-. Values are those stated in the documentation; confirm them against your firmware release.
| Setting | Documented value |
|---|---|
| SMDR RS-232C baud rate choices [800] | 1200 / 2400 / 4800 / 9600 bps |
| SMDR RS-232C data bits [800] | 7 or 8 bits |
| SMDR RS-232C parity [800] | Mark / Space / Even / Odd / None (None is the default) |
| Valid parity + data bits + stop bits combinations when parity is Mark or Space | Mark: 8 data bits, 2 stop bits; Space: 8 data bits, 1 stop bit; Space: 8 data bits, 2 stop bits |
| Line terminator [800] | CR or CR+LF, selectable |
| SMDR page length / skip perforation [801] | Page length 4-99 lines; skip perforation 0-95 lines |
| Incoming/Outgoing Call Selection for Printing [802] | Outgoing: On/Off/Toll; Incoming: On/Off |
| Secret Number SMDR Print Suppression [803] | No Printing / Printing |
| SMDR Account Code mode [805] | CODE or INDEX |
| SMDR Language [806] | English, Spanish, Portuguese, Greek, Czech, Hungarian, Slovak, Polish, Italian |
Switching SMDR output on, as documented
- Program [800] SMDR RS-232C Parameter to set the baud rate, terminator, data bits, parity and stop bits so they match the receiving PC's COM port.
- Program [801] SMDR Parameter to set the page length and skip-perforation line counts for the printout.
- Program [802] to choose whether outgoing calls print On/Off/Toll and incoming calls print On/Off.
- Select SMDR Mode for Printing [929]: MODE 1 for the standard SMDR stream (as in Station Message Detail Recording, 1.20.1.1) or MODE 2 for the alternate per-extension format.
Record format notes
- Two output patterns exist: Pattern A without call-charge information and Pattern B with call-charge information (currency such as EUR shown per call), selected by whether Call Charge Calculation/Call Charge Information SMDR Format 1 [922] is enabled.
- Special call tags shown in the Dial Number field: <incoming> is printed as <I>, <DISA incoming> as <DI>, <DIL incoming> as <LI>, and <UCD waiting> as <UW>.
- Besides the main SMDR stream, section 1.20.1.2 'Call Log Printout for Each Extension' is a separate, selectable per-extension format that prints a header block '* ext : name *' followed by 'Starting Date : mm.dd.yy hh:mmPM' and then that extension's own calls with a running Total charge line; the sample record shown on the page for KX-TEB308 ("* 101 : PEKTOP *" / "Starting Date : Dec.22.08 04:23PM") matches this per-extension format, not the standard SMDR block format.
- Dial number field valid characters are 0-9, comma and #, plus F/ for Flash/Recall and = for a system speed-dial access code; secret/verified account codes can be suppressed from printing via program [803].
Data items: Panasonic KX-TEB308
| Description | Data type | Column name |
|---|---|---|
| Call time | string | CALL_TIME |
| Extension | string | EXT |
| CO | string | TRUNK |
| Direction | string | DIRECTION |
| Dialed number | string | DIALED_PHONE |
| Caller | string | CALLER_PHONE |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Account | string | ACC |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
12/24/08 10:16AM 01 < incoming > .... 12/24/08 10:16AM 101 01 < incoming > 00:00'58" .... Starting Date : Dec.22.08 04:23PM
Panasonic KX-TEM824
Parser: Panasonic KX-TEM824
Connection: Serial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format.
Fields extracted: 9
Data items: Panasonic KX-TEM824
| Description | Data type | Column name |
|---|---|---|
| Call time | datetime | CALL_TIME |
| Extension | string | EXT |
| CO | string | TRUNK |
| Direction | string | DIRECTION |
| Dialed number | string | DIALED_PHONE |
| Caller | string | CALLER_PHONE |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Account | string | ACC |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
<201xxxxxxxxxxx.718> 2/ 3/11 2:38PM 108 04 117 00:00'23" .... <201xxxxxxxxxxx.625> 2/ 3/11 2:37PM 106 05 891xxxxxxxx 00:02'10" .... 2/ 3/11 2:38PM 109 01 < DISA incoming > 00:00'21" .... 0 <201xxxxxxxxxxx.734> 2/ 3/11 2:39PM 108 04 100 00:00'02" .... <201xxxxxxxxxxx.593> 2/ 3/11 2:41PM 101 01 < DISA incoming > 00:00'15" .... 0 <201xxxxxxxxxxx.390> 2/ 3/11 2:38PM 105 02 890xxxxxxxx 00:03'04" .... <201xxxxxxxxxxx.609> 2/ 3/11 2:41PM 109 05 < DISA incoming > 00:00'22" .... 0 <201xxxxxxxxxxx.671> 2/ 3/11 2:44PM 101 01 < DISA incoming > 00:00'27" .... 0 <201xxxxxxxxxxx.203> 2/ 3/11 * 2:44PM 109 01 < DISA incoming > 00:00'21" .... 0 <201xxxxxxxxxxx.625> 2/ 3/11 2:50PM 106 04 8 00:00'03" .... <201xxxxxxxxxxx.531> 2/ 3/11 2:52PM 106 04 892xxxxxxxx 00:00'32" .... 2/ 3/11 2:44PM 105 05 835xxxxxxxx 00:08'07" .... <201xxxxxxxxxxx.500> 2/ 3/11 2:52PM 106 05 892xxxxxxxx 00:00'22" .... <201xxxxxxxxxxx.640> 2/ 3/11 2:52PM 104 04 891xxxxxxxx 00:00'31" .... <201xxxxxxxxxxx.296> 2/ 3/11 2:59PM 101 02 < DISA incoming > 00:00'49" .... 0 <201xxxxxxxxxxx.406> 2/ 3/11 2:53PM 118 05 890xxxxxxxx 00:06'58" .... <201xxxxxxxxxxx.656> 2/ 3/11 3:00PM 101 04 < DISA incoming > 00:00'36" .... 0 <201xxxxxxxxxxx.031> 2/ 3/11 3:02PM 106 05 557xxxx 00:01'17" .... <201xxxxxxxxxxx.578> 2/ 3/11 * 3:01PM 102 04 < DISA incoming > 00:02'27" .... 0 <201xxxxxxxxxxx.906> 2/ 3/11 3:03PM 101 01 < DISA incoming > 00:01'40" .... 0 <201xxxxxxxxxxx.765> 2/ 3/11 3:07PM 109 05 961xxxx 00:00'54" .... <201xxxxxxxxxxx.281> 2/ 3/11 3:08PM 109 04 892xxxxxxxx 00:00'52" .... <201xxxxxxxxxxx.921> 2/ 3/11 3:09PM 109 05 961xxxx 00:01'21" .... <201xxxxxxxxxxx.984> 2/ 3/11 3:12PM 109 01 < DISA incoming > 00:00'07" .... 0 <201xxxxxxxxxxx.671> 2/ 3/11 3:12PM 109 05 890xxxxxxxx 00:00'25" ....
Connecting the logger
Add a data source in PBX Data Logger that matches the interface named in the section for your variant (RS232, TCP client, TCP server or FTP), then open Modules → Query Parse Filter → Data query, click Setup and select the parser named there.
Panasonic programming software
Panasonic KX-TES and KX-TEM systems are programmed with the KX-TE Maintenance Console from Panasonic or your dealer, or from a proprietary telephone in system programming mode. AGG Software does not distribute the console. PBX Data Logger receives the SMDR output that it switches on.
Reports and a database
Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.
Related Panasonic systems
Panasonic KX-T7436Panasonic KX-TD1232
Panasonic KX-T, KX-TD500, DBS and 576/816 SMDR formats
Panasonic KX-T336100b
Panasonic KX-TD500 v2 (ring)
Panasonic MU
Planet IPX-2000
All supported PBX systems
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.
Related topics: Advanced PBX Data Logger
hereCall logging Call accounting SMDR to SQL SMDR Listener Cables and signals