bg

Siemens Hicom-350H SMDR setup and CDR format

This page shows how to get call records out of the Siemens Hicom-350H into Advanced PBX Data Logger: the connection settings, the parser to select and the 6 fields the logger extracts for reports or a database. The settings apply to our logger; other call accounting software may expect a different configuration.

Quick facts

ItemSiemens Hicom-350H
InterfaceSerial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format.
Parser to selectSiemens Hicom-350H
Fields extracted6
Other Siemens systemsSiemens Hicom, HiPath variants and Rolm CDR formats

Selecting the correct parser for Siemens Hicom-350H

Parser Selection For PBX Data Logger

Siemens Hicom-350H

Siemens Hicom-350H

Data items

DescriptionData typeColumn name
Call timedatetimeCALL_TIME
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
ExternalstringEXT
PhonestringDIALED_PHONE
COstringTRUNK

Sample record

As delivered by the system; phone numbers, names and public addresses are masked.

$10/11/0114:13:4500:00:00114 814xxxxxx            1123VCEBAUD 0    
$10/11/0114:13:0300:00:81113 814xxxxxx            1132VCEBAUD 0    
$10/11/0114:11:0300:03:03311 323xxxx              1112VCEBAUD 0    

Reports and a database

Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.

Related Siemens systems

Siemens Hicom-300H
Siemens Hicom-300H (ANI format)
Siemens Hipath 4000 (CDR Standard Format)
Siemens Hipath 4000 (CDRE)
Siemens Hicom, HiPath variants and Rolm CDR formats
All supported PBX systems

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.