Siemens Hipath-3800 SMDR setup and CDR format
This page shows how to get call records out of the Siemens Hipath-3800 into Advanced PBX Data Logger: the connection settings, the parser to select and the 11 fields the logger extracts for reports or a database. The settings apply to our logger; other call accounting software may expect a different configuration.
Quick facts
| Item | Siemens Hipath-3800 |
|---|---|
| Interface | Serial printer port or LAN, whichever the system uses for SMDR output. The record layout identifies the format. |
| Parser to select | Siemens Hipath-3800 |
| Fields extracted | 11 |
| Other Siemens systems | Siemens Hicom, HiPath variants and Rolm CDR formats |
Selecting the correct parser for Siemens Hipath-3800

Siemens Hipath-3800
Siemens Hipath-3800
Data items
| Description | Data type | Column name |
|---|---|---|
| Call time | datetime | CALL_TIME |
| CO | string | TRUNK |
| External | string | EXT |
| Ring | datetime | RING |
| Call duration | datetime | CALL_DURATION |
| Call duration (s) | integer | CALL_DURATION_S |
| Call type | string | CALL_TYPE |
| Direction | string | DIRECTION |
| Phone | string | DIALED_PHONE |
| Caller phone | string | CALLER_PHONE |
| Cost | float | COST |
Sample record
As delivered by the system; phone numbers, names and public addresses are masked.
12.11.09 17:15:07 13 2514 00:00:37 890xxxxxxxx 2 12.11.09 17:15:16 14 2580 00:00:16 890xxxxxxxx 2 12.11.09 17:15:27 48 2500 00:00:11 2101 2
Siemens programming software
Siemens HiPath 3000 systems (3350, 3500, 3550, 3700, 3750, 3800) are programmed with HiPath 3000 Manager E, which comes from Siemens, Unify or your dealer, not from AGG Software. Call data recording is switched on there; PBX Data Logger receives the records.
Reports and a database
Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.
Related Siemens systems
Siemens Hipath-37xx (Delimited by Pipe)Siemens Hipath-37xx (CSV)
Siemens Rolm 9751 (Compat,no ANI)
Siemens Unify OpenScape Business X8
Siemens Hicom, HiPath variants and Rolm CDR formats
All supported PBX systems
Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.
Related topics: Advanced PBX Data Logger
hereCall logging Call accounting SMDR to SQL SMDR Listener Cables and signals