bg

NEC Univerge SV8100 SMDR setup and formats

This page covers the NEC NEC Univerge SV8100 (General Overseas Format) and NEC Univerge SV8100 variants in Advanced PBX Data Logger. Each section gives the connection settings, the parser to select and the fields the logger extracts for reports or a database; where the setup steps are the same for every variant they are given once. The settings apply to our logger; other call accounting software may expect a different configuration.

Quick facts

ItemNEC Univerge SV8100 SMDR setup and formats
Variants on this pageNEC Univerge SV8100 (General Overseas Format), NEC Univerge SV8100
InterfaceLAN. The PBX accepts a connection on TCP port 60010; the logger connects to the PBX IP address.
Port60010
ParsersNEC Univerge SV8100 (General Overseas Format), NEC Univerge SV8100
Fields extracted9 to 12
Other NEC systemsNEC Electra Elite, Aspire, DS2000, XN120 SMDR formats

Variants on this page

NEC Univerge SV8100 (General Overseas Format)

Parser: NEC Univerge SV8100 (General Overseas Format)
Connection: LAN. The PBX accepts a connection on TCP port 60010; the logger connects to the PBX IP address. Port 60010.
Fields extracted: 12

SV8100

PROG 10-12-01/02: confirm your IP address given for the CPU
PROG 35-01-01: Output Port Type (select: LAN)
PROG 10-20-05: SMDR Output Port (input: 60010)
PROG 14-01-06: SMDR Print-Out (checked)

Repeat for all the trunks necessary

Reboot SV8100

Call logging via LAN

  1. Open your favorite browser.
  2. Navigate to the http://192.168.1.220/ (replace the IP address with the address of your PBX)
  3. Login using the installer name and password (by default: sltech/12345678).
  4. Change the settings below.
  5. Apply the changed settings.

Note 1: The SMDR format (35-01-08) depends on the selected parser type (PBX Data Logger → Configuration → Modules → Parser)

Note 2: The SMDR date format (80-05-01) can be changed on the PBX side or selected in the parser settings (PBX Data Logger → Configuration → Modules → Parser → Setup)

LAN Setup

SMDR Output

SMDR Output Settings

Look also at settings for NEC SL1000.

Data items: NEC Univerge SV8100 (General Overseas Format)

DescriptionData typeColumn name
Record numberstringFLAG1
Call typestringCALL_TYPE
DirectionstringDIRECTION
Call timedatetimeCALL_TIME
COstringTRUNK
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
ExtstringEXT
Dialed phonestringDIALED_PHONE
Caller phonestringCALLER_PHONE
AccountstringACC
RingdatetimeRING

Sample record

As delivered by the system; phone numbers, names and public addresses are masked.

NAME 12:31 08/09 001  00:00:17 1401       973xxxxxxx           NEWFOUNDLAND,NJ  
POT  12:31 08/09 023  00:00:47 1265       011xxxxxxxxxxx                        
POT  12:35 08/09 023  00:00:49 1534       120xxxxxxxx                           

NEC Univerge SV8100

Parser: NEC Univerge SV8100
Connection: LAN. The PBX accepts a connection on TCP port 60010; the logger connects to the PBX IP address. Port 60010.
Fields extracted: 9

SV8100

PROG 10-12-01/02: confirm your IP address given for the CPU
PROG 35-01-01: Output Port Type (select: LAN)
PROG 10-20-05: SMDR Output Port (input: 60010)
PROG 14-01-06: SMDR Print-Out (checked)

Repeat for all the trunks necessary

Reboot SV8100

Call logging via LAN

  1. Open your favorite browser.
  2. Navigate to the http://192.168.1.220/ (replace the IP address with the address of your PBX)
  3. Login using the installer name and password (by default: sltech/12345678).
  4. Change the settings below.
  5. Apply the changed settings.

Note 1: The SMDR format (35-01-08) depends on the selected parser type (PBX Data Logger → Configuration → Modules → Parser)

Note 2: The SMDR date format (80-05-01) can be changed on the PBX side or selected in the parser settings (PBX Data Logger → Configuration → Modules → Parser → Setup)

LAN Setup

SMDR Output

SMDR Output Settings

Look also at settings for NEC SL1000.

Data items: NEC Univerge SV8100

DescriptionData typeColumn name
Call typestringCALL_TYPE
DirectionstringDIRECTION
Call timedatetimeCALL_TIME
COstringTRUNK
Call durationdatetimeCALL_DURATION
Call duration (s)integerCALL_DURATION_S
ExtstringEXT
Dialed phonestringDIALED_PHONE
AccountstringACC

Sample record

As delivered by the system; phone numbers, names and public addresses are masked.

IVOT 10:17 05/09 030  00:06:33 310        700xxxxx                               
NAME 10:20 05/09 024  00:03:54 316        008xxxxxxxx                            
ITRS 10:17 05/09 009  00:06:59 138        040xxxxxxx                             

Connecting the logger

All variants on this page use the same connection settings; the steps below apply to each of them.

Configuring PBX Data Logger as a TCP client

Our software should work in the TCP client mode. It means that our software will initiate connection with the PBX and the PBX will work as a server. Add one or several PBX IP addresses here (the IP address of the NEC SV8100). The port number should match the port that you have defined within the PBX (60010 in the example below).

1. Add a new configuration with the TCP data source (if you didn't it before).

TCP/IP Data Interface

2. Configure the TCP settings as shown below.

TCP Client Mode - NEC SV8100

192.168.1.220

60010

192.168.1.220:60010

Selecting the correct parser for NEC Univerge SV8100 (General Overseas Format)

Parser Selection For PBX Data Logger

NEC Univerge SV8100 (General Overseas Format)

NEC Univerge SV8100 (General Overseas Format)

NEC programming software

NEC SL1000, SL1100, SL2100, SV8100 and SV9100 systems are programmed with NEC's PCPro application or the WebPro browser interface built into the system. PCPro comes from NEC or your dealer, not from AGG Software. The SMDR settings on this page are made there; PBX Data Logger receives the records they switch on.

Reads NEC Univerge SV8100 records over TCP port 60010. Parsers for both models on this page are built in.

Reports and a database

Once records arrive, the logger writes them to a text file or to any ODBC database in real time, or hands them to the PBX Reports utility for manual, scheduled and e-mailed reports with a built-in web server. See exporting call log data to a database for the database setup.

Related NEC systems

NEC Topaz
NEC SV9300
NEC XN 120
NEC Electra Elite, Aspire, DS2000, XN120 SMDR formats
NEC Xen Axis (CSV)
All supported PBX systems

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.