Carlo Gavazzi (WM14, CPT A) logging. MODBUS registers map.


This data is being extracted with the help of the Advanced Serial Data Logger (MODBUS RTU,ASCII) or Advanced TCP/IP Data Logger (MODBUS TCP) software only. It may not applicable for other software titles.

MODBUS offsetDescriptionUnitsData type
2V L2 N single
4V L3 N single
6V L1 L2 single
8V L2 L3 single
10V L3 L1 single
12A L1 single
14A L2 single
16A L3 single
18A N single
20W L1 single
22W L2 single
24W L3 single
26Va L1 single
28Va L2 single
30Va L3 single
32Var L1 single
34Var L2 single
36Var L3 single
38Phase sequence single
40Pf L1 single
42Pf L2 single
44Pf L3 single
46V L N single
48V L L single
50W single
52Va single
54Var single
56Pf single
58Hz single
60Asymmetry L N single
62Asymmetry L L single
96A max single
98A max dmd single
100A L1 max single
102A L2 max single
104A L3 max single
106W L1 max single
108W L2 max single
110W L3 max single
112W max dmd single
114Va max dmd single
134V L1 max single
136V L2 max single
138V L3 max single
116Pf L1 min single
118Pf L2 min single
120Pf L3 min single
122A L1 min single
124A L2 min single
126A L3 min single
There are more MODBUS items for this device. Please, download the program.

Note: Products and companies mentioned here are used only for definition and identification purposes and can be trademarks and/or registered trademarks of the respective companies.